2

Hazardous Location Classification & Compliance Services in Ontario

HITE Engineering provides hazardous location classification and engineering support for Ontario industrial and commercial facilities where flammable vapours, combustible dusts, gases, or other materials may create fire or explosion risks.
Our team helps facility managers, plant managers, health and safety leaders, and project teams assess hazardous areas, understand classification requirements, and determine what engineering or compliance steps may be needed.
Hazardous Locations

Engineering for Hazardous Location Compliance & Risk Mitigation

Facilities that handle flammable vapours, dusts, or fibers must meet strict hazardous location compliance requirements under Ontario and Canadian electrical codes. At HITE Engineering, we specialize in hazardous area classification, electrical design reviews, and documentation to ensure your workplace is safe, legally compliant, and operating without risk of fire or explosion.

From manufacturing and processing plants to plating rooms and fuel-handling areas, our team supports facility owners, employers, and consultants in identifying and managing hazardous environments in line with Section 18 of the Ontario Electrical Safety Code, NFPA 70, and CSA/IEC standards.

What Qualifies as a Hazardous Location?

A hazardous location is any area where flammable substances vapours, gases, dusts, or fibres may be present in sufficient quantities to create a fire or explosion risk. The classification depends on the type of material and how often it is present:

  • Class I: Flammable gases or vapours (e.g., natural gas, gasoline)
  • Class II: Combustible dusts (e.g., grain dust, metal dust)
  • Class III: Ignitable fibers or flyings (e.g., textiles, wood shavings)

Examples of Hazardous Locations:

  • Fuel storage or transfer areas
  • Chemical processing plants
  • Grain handling or food processing facilities
  • Plating and brush coating rooms
  • Paint spray booths

HITE has experience providing engineering support across these and other high-risk sectors.

De-Classifying A Hazardous Location

When You May Need Hazardous Location Classification

A hazardous location classification review may be appropriate when a facility introduces new equipment or processes, modifies an existing operation, or needs to confirm whether an area is properly classified.

Common situations include:

  • Flammable vapours or gases
  • Combustible dust
  • Spray painting or coating processes
  • Chemical handling or processing
  • Solvent storage, transfer, or dispensing
  • Fuel or gas-related processes
  • Dust collection systems
  • Flammable liquid storage
  • Processes with ignition or explosion risk
  • New or modified electrical equipment in potentially hazardous areas
  • Facility changes affecting ventilation or process layout
  • Existing hazardous location classifications that may be outdated

Facilities that store or use solvents and similar materials may also need to consider flammable liquid safety in Ontario alongside hazardous location requirements.

Hazardous Area Classification Services

We help clients assess and document hazardous areas through detailed evaluation and certified engineering reports.

Services Include:

  • Zone Classification: Class I Division 1 / 2 or Class I Zone 0 / 1 / 2, as per Ontario Electrical Code Rule 18-004
  • Hazard Mapping: AutoCAD-based classification drawings indicating the extent of hazardous zones
  • Ventilation-Based Volume Calculations: Using proven methods to minimize classified zones
  • Equipment Review & Selection: Ensuring installed components are properly rated by Division, Group, and Temperature Code
  • Combustible Gas Detection: Application of Rule 18-070 for mitigation of risk and classification through the use ofgas detection systems

We also provide support for Electrical Safety Authority (ESA) Deviation Requests where non-hazardous-rated equipment is used with gas detection fallback controls.

Applicable Standards and Codes

HITE Engineering delivers consultation and documentation using all relevant codes and cross-border standards where most applicable, including:

  • Ontario Electrical Safety Code (OESC) Section 18
  • CSA C22.1 and C22.2 Standards
  • NFPA 70 / NEC Article 500
  • UL / FM Global Ratings
  • ATEX and IECEx International Systems

Many of our clients bring in foreign equipment (e.g., from Europe or the U.S.) that requires evaluation and documentation to meet local Ontario or CSA standards. We provide the engineering analysis and documentation needed for proper certification.

Common Compliance Challenges Solved

We’re often called in to resolve issues such as:

  • Missing or outdated classification drawings
  • Installation of non-compliant equipment without gas detection systems
  • Lack of ventilation analysis for controlling classified area size
  • No formal documentation for audit or insurer requirements

Real-world examples from recent projects include:

  • Classification and declassification of a baler room at a packaging facility (Class I Zone 2)
  • Full documentation and ESA support for a brush plating room at an aerospace facility
  • Combustible gas detection integration to allow non-hazardous rated equipment use

Combustible Dust, Ignition Risk and PSR/PHSR Connections

Hazardous location classification can overlap with Ontario's Pre-Start Health and Safety Review requirements when processes involve combustible dust, flammable materials, or other ignition and explosion hazards.
A hazardous location classification and a PSR/PHSR are not necessarily the same review. The requirements depend on the process, materials, equipment, and applicable circumstances.

Dust Collectors

Processes that generate combustible dust may require review of both the process area and associated dust collection systems.

Dust properties, collection equipment, potential ignition sources, equipment location, and operating conditions may all affect the assessment.

Risk of Ignition or Explosion

A Risk of Ignition or Explosion PSR/PHSR may apply where materials, vapours, dusts, equipment, or processes create conditions that require engineering review under Ontario’s PSR framework.

Flammable Liquid Storage

Facilities that store, transfer, dispense, or use flammable liquids may also need to consider Flammable Liquid Storage PSR/PHSR requirements, depending on the installation and process.

HAZOP and Risk Analysis

Where a broader process review is needed, HITE provides HAZOP and Risk Analysis to identify potential process deviations, consequences, safeguards, and areas requiring further engineering review.

What We Review

A hazardous location classification review is specific to the materials, processes, equipment, and operating conditions within the facility.

Depending on the project, we may review:

  • Process and material information
  • Safety Data Sheets
  • Facility and equipment layouts
  • Flammable gases and vapours
  • Combustible dusts or fibers
  • Material release points
  • Ventilation and exhaust systems
  • Potential ignition sources
  • Electrical equipment and installations
  • Existing hazardous area classifications
  • Classification drawings
  • Gas detection systems
  • Dust collection systems
  • Applicable codes and standards
  • PSR/PHSR considerations where applicable
  • Compliance and documentation gaps

The goal is to understand where hazardous conditions may occur, how classified areas may extend, and what engineering or documentation may be required.

Our Hazardous Location Review Process

HITE follows a clear hazardous location classification process so clients know what to expect from the review.
01
Step 1

Intake and Data Collection

We begin by reviewing available project information. This may include facility layouts, process descriptions, Safety Data Sheets, electrical drawings, ventilation information, equipment details, photos, and existing classification documents.

02

Step 2

Process and Material Review

Our team reviews the materials being handled, stored, transferred, or generated and the conditions under which gases, vapours, dusts, or fibers may be released.
We also review applicable codes, standards, and existing documentation to identify areas that require closer assessment.
03
Step 3

Site Visit Where Required

A site visit may be needed to confirm equipment locations, process conditions, ventilation, release points, potential ignition sources, and existing electrical installations.
Not every initial review requires a site visit, but many formal classification projects do.
04
Step 4

Engineering Assessment

HITE evaluates the facility conditions and determines the appropriate hazardous location classification based on the materials, processes, ventilation, potential releases, and applicable requirements.
Where relevant, our team also identifies electrical classification considerations, combustible dust concerns, or potential PSR/PHSR connections.
05
Step 5

Report and Follow-Up

Where applicable, HITE provides an engineering report and supporting classification documentation outlining findings and recommendations.
If equipment, ventilation, processes, or facility layouts change after the review, our team can provide follow-up assessment or updated documentation where required.
Industrial warehouse pallet racking system requiring engineering review under Ontario Regulation 851 and CSA A344

What You Receive

The deliverables depend on the process, materials, facility conditions, available documentation, and scope of the classification review.

A hazardous location project may include:

  • Hazardous location classification assessment
  • Site inspection where required
  • Process and material review
  • Electrical area classification considerations
  • Hazardous area identification
  • Classification drawings or maps where applicable
  • Ventilation or emissions review where applicable
  • Engineering recommendations
  • Compliance gap identification
  • Signed and sealed engineering report where applicable
  • ESA support where required
  • PSR/PHSR direction where applicable
  • Follow-up engineering support
30+
Years of Industry Experience

Why Choose Us

Clients partner with HITE Engineering when they need hazardous location engineering support that is technical, practical, and grounded in real industrial conditions.
Our team helps clients understand where hazardous areas may exist, what classification requirements need to be considered, and what engineering documentation may be required.

Founded in 1997

HITE Engineering has supported Ontario workplaces since 1997, including manufacturing plants, processing facilities, warehouses, commercial properties, and other industrial environments.

Hazardous Location Engineering & Documentation

Our team understands hazardous area classification, electrical classification considerations, ventilation, combustible dust, flammable vapours, gas detection, and related compliance requirements.
Where applicable, HITE can provide engineering reports, classification drawings, recommendations, and supporting documentation.

Industry Leadership & Trusted Experience

Our experience is supported by licensed Professional Engineers, CSA technical committee involvement, former Ministry of Labour consulting experience, and projects across industrial, municipal, institutional, and commercial environments.

Practical Recommendations

Clients need more than a classification on a drawing. HITE focuses on recommendations that can be understood and applied when selecting equipment, modifying processes, addressing deficiencies, or planning facility changes.

Ontario-Wide Service

We're proud to support hazardous location and area classification projects for clients across Ontario.

FAQs

Hazardous location classification identifies areas where flammable gases, vapours, combustible dusts, or ignitable fibers may create conditions with a potential fire or explosion risk.

The classification helps define where specific electrical, equipment, ventilation, or other safety considerations may apply.

Combustible dust may create a hazardous location concern where dust is generated, released, dispersed, or accumulated under conditions that could create a fire or explosion hazard.

The material, process, concentration, ventilation, dust collection equipment, and potential ignition sources should be considered when assessing the area.

No. Hazardous location classification identifies and documents areas where hazardous atmospheres or materials may be present. A PSR/PHSR is an engineering review required under specific circumstances in Ontario Regulation 851.

The two can overlap where a process involves combustible dust, flammable materials, or another risk of ignition or explosion.

Yes. HITE already provides AutoCAD-based hazard mapping and classification drawings showing the extent of hazardous zones as part of applicable projects.

Useful information may include:

  • Facility and process drawings
  • Equipment layouts
  • Process descriptions
  • Safety Data Sheets
  • Material information
  • Ventilation information
  • Electrical drawings
  • Dust or material testing information where available
  • Existing hazardous location classifications
  • Previous engineering or PSR/PHSR documentation

The specific information required depends on the facility and scope of the review.

Yes. A review may be appropriate when processes, materials, ventilation, equipment, or facility layouts have changed, or when existing hazardous location documentation is missing or outdated.

HITE can assess current conditions and determine what classification or engineering documentation may be required.

Yes. Changes to ventilation, material handling, equipment, release points, or process conditions can affect the location or extent of a classified area.

An engineering review can help determine whether an existing classification should be updated to reflect the new operating conditions.

Start With a Free Consultation

Whether you’re designing a new process area, upgrading equipment, or addressing ESA deficiencies, HITE can help you ensure full hazardous location compliance.
Contact us today to speak to a licensed professional engineer or request a site classification audit via our contact form